VizieR

CfA VizieR . ADAC VizieR . Cambridge (UK) VizieR . IUCAA VizieR . INASAN VizieR .

VizieR

Simple TargetList Of TargetsFast Xmatch with large catalogs or Simbad
Target Name (resolved by Sesame) or Position:
Target dimension:
NB: The epoch used for the query is the original epoch of the table(s)Radius Box size

  
J/ApJ/738/129
  XMM-Newton X-ray sources in NGC 6553 (Guillot+, 2011)
Post annotation
img(gal)
1.J/ApJ/738/129/table1(c)X-ray Sources Detected in the XMM Observation of NGC 6553 (43 rows)
2.J/ApJ/738/129/table2Spectral Results of X-ray Sources in NGC 6553 (43 rows)

 
Query by Constraints constraints help applied on Columns (Output Order: + - )
ShowSortJoin tables
more join
Column  Constraint Explain   (UCD)
  (ALL)recno  Record number assigned by the VizieR team. Should Not be used for identification. (meta.record)
  (1)Name (char) Object name (XMMU JHHMMSS+DDMMSS) (meta.id;meta.main)
  (1)RAJ2000 deg (i) Right Ascension in decimal degrees (J2000) (pos.eq.ra;meta.main)
  (1)e_RAJ2000 arcsec Uncertainty in RAdeg (stat.error;pos.eq.ra)
  (1)DEJ2000 deg (i) Declination in decimal degrees (J2000) (pos.eq.dec;meta.main)
  (1)e_DEJ2000 arcsec Uncertainty in DEdeg (stat.error;pos.eq.dec)
  (1)S/N  Detection significance provided by wavdetect (stat.snr)
   (ALL)ID   [01/43] Source identifier (meta.id)
  (2)pnRate ct/ks Background subtracted count rates in the 0.3-10 keV range (phot.count;em.X-ray)
  (2)e_pnRate ct/ks Uncertainty in pnRate (stat.error)
  (2)n_pnRate (char) [a] Note on pnRate (Note 1)   (meta.note)

ALL cols
    
 (i)indexed column
  (2)Gamma  (n) Best-fit photon index when a power law (PL) model was used (meta.code;spect.index;meta.modelled)
  (2)n_Gamma (char) [)] Note on Gamma (Note 2)   (meta.note)
  (2)E_Gamma  (n) Upper limit uncertainty in Gamma (stat.error;stat.max)
  (2)e_Gamma  (n) Lower limit uncertainty in Gamma (stat.error)
  (2)kTeff keV (n) Best-fit effective temperature when a thermal model was used (phys.temperature.effective)
  (2)E_kTeff keV (n) Upper limit uncertainty in kTeff (stat.error;stat.max)
  (2)e_kTeff keV (n) Lower limit uncertainty in kTeff (stat.error)
  (2)kTeff1 keV (n) Best-fit effective temperature when a thermal model was used (phys.temperature.effective)
  (2)E_kTeff1 keV (n) Upper limit uncertainty in kTeff1 (stat.error;stat.max)
  (2)e_kTeff1 keV (n) Lower limit uncertainty in kTeff1 (stat.error)
  (2)FX 10-16W/m2Unabsorbed X-ray flux in the band 0.5-10 keV (10-13 erg/cm2/s) (Note 3)   (phot.flux;em.X-ray)
  (2)chi2  χ2 statistic of the fit (stat.weight;stat.fit.param;meta.modelled)
  (2)dof   [3/115] Number of degrees of freedom (meta.number)
  (2)Prob   [0/1] Null hypothesis probability (stat.probability)
  (2)Model (char) Model used (Note 4)   (instr.setup;meta.modelled)

ALL cols
    
(n) indicates a possible blank or NULL column(i)indexed column
Adapt form
Display your selection only Reset to default columns
usage  Display UCD1+    UCD1  
elapse time 1