title low-den continuous HI emission with 2-nu important c c commands controlling continuum ========= laser 2 ionization -1 c c commands for density & abundances ========= hden 0 init "honly.ini" c c commands controlling geometry ========= stop thickness 0 c c other commands for details ========= c increase default resolution stored in continuum_mesh.ini set continuum resolution 0.1 case b iterate constant temperature 4 c c commands controlling output ========= print lines column save overview "h_t4_conemis_lon.ovr" save performance "h_t4_conemis_lon.per" save continuum "h_t4_conemis_lon.con" last units microns save two photon continuum "h_t4_conemis_lon.2nu" last rydbergs save spectrum "h_t4_conemis_lon.ncon" last units microns save monitors "h_t4_conemis_lon.asr" c c commands giving the monitors ========= monitor line "nFnu" 122.4m -26.458 luminosity monitor line "nFnu" 60.83m -26.214 luminosity monitor line "nFnu" 41.22m -26.078 luminosity monitor line "nFnu" 30.87m -25.976 luminosity monitor line "nFnu" 24.78m -25.899 luminosity monitor line "nFnu" 24.30m -25.892 luminosity monitor line "nFnu" 22.83m -25.869 luminosity monitor line "nFnu" 21.42m -25.847 luminosity monitor line "nFnu" 21.12m -25.843 luminosity monitor line "nFnu" 19.62m -25.815 luminosity monitor line "nFnu" 17.65m -25.776 luminosity monitor line "nFnu" 17.37m -25.771 luminosity monitor line "nFnu" 15.69m -25.737 luminosity monitor line "nFnu" 14.60m -25.709 luminosity monitor line "nFnu" 12.43m -25.650 luminosity monitor line "nFnu" 11.40m -25.622 luminosity monitor line "nFnu" 10.46m -25.586 luminosity monitor line "nFnu" 9.480m -25.555 luminosity monitor line "nFnu" 9.325m -25.550 luminosity monitor line "nFnu" 8.210m -25.499 luminosity monitor line "nFnu" 7.580m -25.475 luminosity monitor line "nFnu" 7.050m -25.438 luminosity monitor line "nFnu" 4.114m -25.231 luminosity // >>chng 11 oct 12, from -25.06 to -25.04, scale iso highest pcs to be consistent with recomb topoff monitor line "nFnu" 2.324m -25.04 luminosity // // >>chng 02 jul 19, to case b, from -24.924 to 892 monitor line "nFnu" 1.643m -24.892 luminosity // // >>chng 07 feb 06, bugfix in r828, from -24.897 to -24.878 monitor line "nFnu" 1.480m -24.878 luminosity // monitor line "nFnu" 1.436m -24.718 luminosity // // >>chng 02 jul 19, to case b, all following got brighter monitor line "nFnu" 1.119m -24.688 luminosity // monitor line "nFnu" 8330A -24.676 luminosity monitor line "nFnu" 8079A -24.324 luminosity monitor line "nFnu" 6210A -24.361 luminosity monitor line "nFnu" 4885A -24.377 luminosity monitor line "nFnu" 3704A -24.315 luminosity monitor line "nFnu" 3588A -23.628 luminosity monitor line "nFnu" 2430A -23.868 luminosity // peak of 2nu emission monitor line "nFnu" 2392A -23.870 luminosity monitor line "nFnu" 2071A -23.849 luminosity monitor line "nFnu" 2053A -23.846 luminosity monitor line "nFnu" 1793A -23.787 luminosity monitor line "nFnu" 1585A -23.736 luminosity monitor line "nFnu" 1458A -23.727 luminosity monitor line "nFnu" 1357A -23.775 luminosity // c h_t4_conemis_lon.in c class limit c ======================================== c This is a mate to hatomt10.in except that the density is low enough for two-photon emission to be very imporant in the optical and uv.