title background cosmic ray ionization by suprathermal electrons only c c commands controlling continuum ========= cosmic ray rate -16 c this will be VERY faint black 50000 ionization parameter -25 black 50000 c c commands for density & abundances ========= hden 5 element hydrogen ionization 1 0.00000001 c c commands controlling geometry ========= set dr 0 stop zone 1 c c other commands for details ========= constant temperature 1000 K c turn off molecules to test only ions no molecules c must turn off charge transfer and its heating, which would dominate, c since we want to test cr heating and ionization no charge transfer no ctheat c must turn of photoionization by recombining species, c since we want to test cr heating and ionization no photoionization c any time photoionization is turned off, it is best to also c turn off induced processes, which include pumping in the lyman lines no induced processes c c commands controlling output ========= print ages // >>chng 01 may 11, model was changed to test only secondary ionization, // its intended purpose save overview "ism_set_cr_rate.ovr" save performance "ism_set_cr_rate.per" save monitors "ism_set_cr_rate.asr" last c c commands giving the monitors ========= // // this is log of H0 ionization rate monitor csupra -16.00 // // total heating // uncertain since depends on collider density // >>chng 11 nov 16, from -22.04 to -22, adjust newmole monitors monitor htot -22.00 // // >>chng 11 nov 16, from -22.04 to -22, adjust newmole monitors monitor line "cr h" 0 luminosity -22 // // >>chng 08 jul 26, add two hyperfine stucture lines // asserted values not yet set monitor line "H 1" 21.10c luminosity -26.696 monitor line "Mg 2" 16.00c luminosity -35.662 // monitor ionization helium 2 -4.14 error 0.1 // // >>chng 06 mar 05, from -4.27 to -8.05, NA add C+ - (Mg0 Fe0) CT // >>chng 08 dec 18, from -8.05 to -4.27, prev chg reversed; CT now properly killed monitor ionization carbon 2 -4.27 error 0.1 // // >>chng 06 mar 05, from -4.50 to -7.19, NA add C+ - (Mg0 Fe0) CT // >>chng 08 dec 18, from -7.19 to -4.50, prev chg reversed; CT now properly killed // >>chng 11 jul 12, from -4.5 to -4.304, update to head of branch, without new coll DR suppression // >>chng 12 jul 01, from -4.304 to -4.76, update Badnell DR to 13-electron iso sequence // >>chng 12 aug 24, from -4.76 to -4.836, BUGFIX r6603 DR rates not updated in const temp sim // >>chng 13 feb 02, from -4.836 to -4.967, BUGFIX, largely undo r6703 monitor ionization silicon 2 -4.967 error 0.1 // // >>chng 06 feb 07, from -4.02 to -3.97, add exp to low-T DR // >>chng 11 apr 22, from -3.97 to -4.042, update Ar sequence Badnell DR rates // >>chng 11 jul 12, from -4.042 to -3.987, enable fit to Badnell DR suppression // >>chng 13 feb 02, from -3.987 to -4.029, BUGFIX, largely undo r6703 monitor ionization iron 2 -4.029 error 0.1 // c ism_set_cr_rate.in c class limit c ======================================== c This test conditions of cosmic ray ionization. Molecules and charge transfer are disabled so that analytical estimates can be made.