title Test model H and He atoms in Case B limit c grid over nebular range of density and temperature to check Case B H & He c c commands controlling continuum ========= c create H+ and He+ laser 2.0 Ryd ionization parameter -2 c c commands for density & abundances ========= init "hheonly.ini" hden 2. vary grid 2 6 2 c c commands controlling geometry ========= stop zone 1 c c other commands for details ========= set line precision 5 atom he-like element helium resolved levels 10 no scattering escape case b hummer no Pdest no photoionization constant temperature 4. c c commands controlling output ========= atom H-like print levels save overview "limit_caseb_hhe_den.ovr" save performance "limit_caseb_hhe_den.per" save monitors "limit_caseb_hhe_den.asr" c c commands giving the monitors ========= monitor Case B H-like Hydrogen error 0.08 range 1000A to 40000A c Case B helium doesn't work well with Hummer option c monitor Case B He-like Helium error 0.05 range 1000A to 13000A faint -2.0 c c limit_caseb_hhe_den.in c class limit c ======================================== c this tests the predicted H I and He I spectra in the Case B limit. the grid is over density at the standard temperature of 1e4 K.