title test ots, inward fractions for pure hydrogen, open geo, filling factor c c commands controlling continuum ========= ionization -2 blackbody 40000 c c commands for density & abundances ========= hden 5 init file "honly.ini" c c commands controlling geometry ========= stop efrac 0.05 %stop when 5 percent ionized constant temper 7500 filling factor 0.01 c c other commands for details ========= c must iterate to get inward line fractions, that are asserted below iterate diffuse ots c not iterating does not affect the solution no level2 no induced processes (OK) c c commands controlling output ========= print line inward save performance "h_otsopen.per" save overview "h_otsopen.ovr" last save dr "h_otsopen.dr" last save monitors "h_otsopen.asr" last save continuum "h_otsopen.con" last units angstrom normalize to "Ca B" 4861 = 1 % normalize to exact result c c commands giving the monitors ========= c this is an open geometry, so do not expect H atom to exactly be case B c due to Lyman line leakage. we iterated, so have a good estimate of c inward and outward fractions, which we test monitor line "Q(H)" 4861 >1.0 % // // >>chng 08 apr 30, from 1.00 to 1.057 H, He topoff change monitor line "Q(H)" 4861 1.057 % // monitor line "Q(H)" 4861 < 1.1 %>but not a lot less // //>>chnn 99jun26, error had been just under 2%, increased above it when optical // depths of 2s and 2p were brought together, so increased error // >>chng 08 apr 30, from 1 to 0.968 H, He topoff change monitor line "H 1" 4861 = 0.968 error 0.03 %no surprise if not unity, since open // // >>chng 08 apr 30, from 0.5 to 0.484 H, He topoff change monitor line "Inwd" 4861 =0.484 error 0.03 %no surprise if not unity, since open // monitor line "nFnu" 3588 = 18.0 error 0.02 %total Balmer continuum rel to h-beta monitor line "InwT" 3588 = 9.00 error 0.02 %inward Balmer continuum rel to h-beta // // >>chng 01 aug 23, from 18.26 to 18.633, 2x better continuum resolution monitor line "BaC " 3646 = 18.633 error 0.02%residual Balmer continuum rel to h-b // // >>chng 01 aug 23, from 9.07 to 9.319 2x better continuum resolution monitor line "cout" 3646 = 9.319 error 0.02 %Balmer continuum rel to h-beta // >>chng 01 aug 23, from 9.07 to 9.319 2x better continuum resolution monitor line "cref" 3646 = 9.319 error 0.02 %Balmer continuum rel to h-beta c h_otsopen.in c class limit c ======================================== c This tests the total emission from a hydrogen Stromgren sphere using the OTS approximation. The conservation of the total number of ionizing photons, and the emitted spectrum, are all checked.