title continuous emission from HeI c c commands controlling continuum ========= laser 1.9 ryd ionization -1 c c commands for density & abundances ========= c need high density to supress two-photon emission hden 10 c force high density for electrons, He+ density will be the same set eden 12 c set He/H ratio to 100, He and elec will have same density element abundance helium 2 init "hheonly.ini" c c commands controlling geometry ========= c this thickness will get unit emission when combined with above densities stop thickness -24 c c other commands for details ========= iterate constant temperature 4 c c commands controlling output ========= c // increase continuum resolution by factor of ten set continuum resolution 0.1 // // include only the diffuse components in this set nFnu diffuse outward, diffuse inward // print line faint 1 print line column // save overview "heatomt10.ovr" save performance "heatomt10.per" save spectrum "heatomt10.spc" last no title units microns save continuum "heatomt10.con" last no title units microns save diffuse continuum "heatomt10.dif" last no title units microns save monitors "heatomt10.asr" c c commands giving the monitors ========= // >>chng 02 may 27, all following to 4.11 micron changed as result // of better gaunt factors // >> all following, through 2 micron, got fainter by ~10 percent // as result of improved brems gaunt factors, better sum over species monitor line luminosity "nFnu" 122.4m -26.446 monitor line luminosity "nFnu" 60.83m -26.215 monitor line luminosity "nFnu" 41.22m -26.082 monitor line luminosity "nFnu" 30.87m -25.984 monitor line luminosity "nFnu" 24.78m -25.901 monitor line luminosity "nFnu" 24.30m -25.903 // >>chng 11 oct 12, from -25.88 to -25.86, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 22.83m -25.86 // >>chng 11 oct 12, from -25.86 to -25.84, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 21.42m -25.84 // >>chng 11 oct 12, from -25.86 to -25.84, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 21.12m -25.84 // >>chng 11 oct 12, from -25.83 to -25.81, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 19.62m -25.81 // >>chng 11 oct 12, from -25.79 to -25.77, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 17.65m -25.77 // >>chng 11 oct 12, from -25.79 to -25.76, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 17.37m -25.76 // >>chng 11 oct 12, from -25.75 to -25.73, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 15.69m -25.73 // >>chng 11 oct 12, from -25.72 to -25.7, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 14.60m -25.7 // >>chng 11 oct 12, from -25.66 to -25.64, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 12.43m -25.64 // >>chng 11 oct 12, from -25.64 to -25.62, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 11.40m -25.62 // // >>chng 07 feb 06, bugfix in r828, from -25.602 to -25.583 monitor line luminosity "nFnu" 10.46m -25.583 // // >>chng 11 oct 12, from -25.57 to -25.55, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 9.480m -25.55 // >>chng 11 oct 12, from -25.57 to -25.54, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 9.325m -25.54 // // >>chng 07 feb 06, bugfix in r828, from -25.515 to -25.496 monitor line luminosity "nFnu" 8.210m -25.496 // // >>chng 11 oct 12, from -25.49 to -25.47, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 7.580m -25.47 // >>chng 11 oct 12, from -25.45 to -25.43, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 7.050m -25.43 // >>chng 11 oct 12, from -25.25 to -25.23, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 4.114m -25.23 // >>chng 11 oct 12, from -25.07 to -25.05, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 2.324m -25.05 // >>chng 02 may 27, end changes in continuum // >>chng 02 jun 21, end changes in continuum monitor line luminosity "nFnu" 1.643m -24.927 monitor line luminosity "nFnu" 1.480m -24.923 monitor line luminosity "nFnu" 1.436m -24.776 monitor line luminosity "nFnu" 1.119m -24.744 monitor line luminosity "nFnu" 8330A -24.804 monitor line luminosity "nFnu" 8079A -24.511 // >>chng 11 oct 12, from -24.47 to -24.45, scale iso highest pcs to be consistent with recomb topoff monitor line luminosity "nFnu" 6210A -24.45 monitor line luminosity "nFnu" 4885A -24.598 // >>chng 01 dec 28, nearly all of following reset monitor line luminosity "nFnu" 3704A -24.861 monitor line luminosity "nFnu" 3588A -24.340 // >>chng 02 apr 16, nearly all of following reset monitor line luminosity "nFnu" 2392A -23.998 monitor line luminosity "nFnu" 2071A -24.278 monitor line luminosity "nFnu" 2053A -24.298 monitor line luminosity "nFnu" 1793A -24.619 monitor line luminosity "nFnu" 1585A -24.968 monitor line luminosity "nFnu" 1458A -25.237 monitor line luminosity "nFnu" 1357A -25.491 monitor line luminosity "nFnu" 1297A -25.661 monitor line luminosity "nFnu" 1263A -25.766 monitor line luminosity "nFnu" 1218A -25.911 monitor line luminosity "nFnu" 1196A -25.984 monitor line luminosity "nFnu" 1175A -26.059 monitor line luminosity "nFnu" 1144A -26.172 // >>chng 09 feb 24, from -26.29 to -26.31, botches due to r2763 monitor line luminosity "nFnu" 1113A -26.31 // >>chng 09 feb 24, from -26.32 to -26.35, botches due to r2763 monitor line luminosity "nFnu" 1103A -26.35 // // >>chng 02 jul 19, from -26.433 to -26.458, better two photon // >>chng 05 mar 12, from -26.458 to -26.433, RP merge He-like code monitor line luminosity "nFnu" 1074A -26.433 error 0.1 // // >>chng 02 jul 19, from -26.470 to -26.497, better two photon // >>chng 05 mar 12, from -26.497 to -26.470, RP merge He-like code monitor line luminosity "nFnu" 1064A -26.470 error 0.1 // // >>chng 02 jul 19, from -26.576 to -26.612, better two photon // >>chng 05 mar 12, from -26.612 to -26.575, RP merge He-like code // >>chng 09 feb 24, from -26.57 to -26.62, botches due to r2763 monitor line luminosity "nFnu" 1036A -26.62 error 0.1 // c heatomt10.in c class limit c ======================================== c This tests continuous emission from the He I atom. The laser is used so that the incident continuum is not included in the total emission.